9XCite ‐ PKG ‐ R? ? RS ‐ 232/485 ? RF ? Modem ? – ? Product ? Manual ? v2.1 ? [2007.01.04]
MK (Address Mask) Command
<AT Command: Networking> MK Command is used to set the radio modem address mask. All RF
packets contain the Destination Address of the transmitting radio modem. When an RF packet is
received, the transmitter's Destination Address is logically "ANDed" (bitwise) with the Address
Mask of the receiver. The resulting value must match the Destination Address or the Address Mask
of the receiver for the packet to be received and sent out the receiving modem serial port. If the
"ANDed" value does not match either the Destination Address or the Address Mask of the receiver,
the packet is discarded. (All "0" values are treated as "irrelevant" values and ignored.)
AT Command: MK
Parameter Range: 0 - 0xFFFF
# of bytes returned: 2
Default Parameter Value: 0xFFFF (When set to this value, the Destination Address of the trans-
mitter must exactly match the Destination Address of the receiver.)
Related Commands: DT (Destination Address), HP (Channel)
NB (Parity) Parameter
<Non-AT Settable Parameter: Serial Interfacing>
NB Parameter allows parity for the modem to be
changed. Parity is an error detection method in
Parameter Ranges: 0 - 4
Parameter
Configuration
which a bit (0 or 1) is added to each group of bits
so that it will have either an odd number of 1's or
an even number of 1's. For example, if parity is
odd, then any group of bits that arrives with an
even number of 1's must contain an error.
0
1
2
3
4
8-bit (no parity) or 7-
bit (with any parity)
8-bit even parity
8-bit odd parity
8-bit mark parity
8-bit space parity
Default Parameter Value: 0
Number of bytes returned: 1
PW (Pin Wake-up) Parameter
<Non-AT Settable Parameter: Sleep (Low
Power)> Under normal operation, a radio modem
in Cyclic Sleep Mode cycles from an active state to
a low-power state at regular intervals until data is
ready to be received. If PW Parameter is set to 1,
the SLEEP Pin (Pin 2 of the embedded OEM RF
Module) can be used to awaken the modem from
Cyclic Sleep. If the SLEEP Pin is de-asserted
Parameter Ranges: 0 - 1
Parameter Configuration
0 disabled
1 enabled
Default Parameter Value: 0
Number of bytes returned: 1
(low), the radio modem will be fully operational
and will not go into Cyclic Sleep. Once SLEEP is asserted, the radio modem will remain active for
the period of time specified by ST (Time before Sleep) Command, and will return to Cyclic Sleep
Mode (if no data is ready to be transmitted). PW Command is only valid if Cyclic Sleep has been
enabled using SM Command.
RE (Restore Defaults) Command
<AT Command: AT Command Options> RE Command restores all AT-settable parameters to fac-
tory default settings. However, RE Command will not write the default values to non-volatile mem-
ory. Unless the WR (Write) Command is issued after the RE Command, the default settings will not
be saved in the event of radio modem reset or power-down.
AT Command: RE
Related Command: WR (Write)
? ? 2007 ? MaxStream, ? Inc.
????? 29
相关PDF资料
XC0900A-03S COUPLER 90DEG 811-1000MHZ 3DB
XC1900A-03S COUPLER 90DEG 1700-2000MHZ 3DB
XC2401A8167R-G IC GPS LNA 1.6GHZ USPN-4B02
XC2404A816UR-G IC GPS LNA 1.6GHZ USP-8A01
XE112 LAMP T3-1/4 WITH XE GAS WHITE
XE1203SKC868XE2 KIT STARTER FOR XE1203 868MHZ
XE1205SKC868XE1 KIT STARTER FOR XE1205 868MHZ
XE1283I076TRLF IC TXRX UHF LOW POWER 72-LFBGA
相关代理商/技术参数
XC09-038WNC 功能描述:射频模块 9XCite 4mW transcei e antenna 38400 bps RoHS:否 制造商:Linx Technologies 产品:Transceiver Modules 频带:902 MHz to 928 MHz 输出功率:- 15.5 dBm to + 12.5 dBm 接口类型:UART 工作电源电压:- 0.3 VDC to + 5.5 VDC 传输供电电流:38.1 mA 接收供电电流:22.7 mA 天线连接器类型:U.FL 最大工作温度:+ 85 C 尺寸:1.15 mm x 0.63 mm x 0.131 mm
XC09-038WNI 功能描述:射频模块 9XCite 4mW transcei e antenna 38400 bps RoHS:否 制造商:Linx Technologies 产品:Transceiver Modules 频带:902 MHz to 928 MHz 输出功率:- 15.5 dBm to + 12.5 dBm 接口类型:UART 工作电源电压:- 0.3 VDC to + 5.5 VDC 传输供电电流:38.1 mA 接收供电电流:22.7 mA 天线连接器类型:U.FL 最大工作温度:+ 85 C 尺寸:1.15 mm x 0.63 mm x 0.131 mm
XC-09-201-S 制造商:FLOYD BELL 功能描述:Alarm, Piezoelectric, 82 dBA to 103 dBA @ 2 Ft.,Extra Loud Continuous, 30-120VAC
XC-09-212-S 制造商:FLOYD BELL 功能描述:EXTRA LOUD CONTINUOUS, PANEL MOUNT CASE AND QUICK CONNECT BLADES WITH SCREWS TER
XC-09-212-SR 制造商:FLOYD BELL 功能描述:Alarm, Piezoelectric, 82 dBA to 103 dBA @ 2 Ft., Extra Loud Continuous, 2-12VDC
XC-09-212-W 制造商:FLOYD BELL 功能描述:EXTRA LOUD CONTINUOUS; PANEL MOUNT CASE AND WIRES TERMINATION
XC-09-301-S 制造商:FLOYD BELL 功能描述:Alarm, Piezoelectric, 82 dBA to 103 dBA @ 2 Ft.,Extra Loud Continuous,130-220VAC
XC-09-330-Q 制造商:FLOYD BELL 功能描述:EXTRA LOUD CONTINUOUS; PANEL MOUNT CASE AND QUICK CONNECT BLADES TERMINATION